daniel@sjsjcn.cn    whatsapp:+8615961733235
Equipment maintenance

Introduction of eighth generation infrared ray used in pinch plate production li

Update time:2017-05-15 16:37:48Clicks:2044
The first step: start running the tractor, adjust the speed potentiometer I to the normal drawing board.
The second step: adjust the fiber optic stent, moving the light spot to the edge of the pinch plate. The yellow and green lights change alternately to find the edge of the gusset plate.
The third step: adjust the "speed potentiometer II", from the starting position in the direction of a twist < thin plate > or two circle < thick plate >.
The fourth step: turn on the local switch and enter the infrared local tracking. 1. adjust the speed potentiometer "I" < basic operation > to make the green light even alternately blink. 2. adjust the speed potentiometer II < speed potentiometer II, which belongs to the range deviation adjustment >. According to the needs of production, the thickness of the buckle plate is determined by: sheet <1-3HZ>, thick plate <3-6HZ>. When the traction machine is other manufacturers, it is necessary to consider the speed ratio of the tractor, which can reduce the magnitude of the value of 50%, that is, sheet <0.5-1.5HZ>, heavy plate <1.5-3HZ>. 3 see the seam effect, such as too much support toward the inner direction of fine-tuning, narrow strip. If the material is too small, the bracket will be adjusted in the outer direction and the width of the material belt will be widened.
The fifth step: open the whole track, and enter the infrared tracking state. If closed for some reason, return to local status. When this is done, the part is closed and returned to the normal state.
The sixth step: if the operation is not normal, you can first check whether the infrared is normal. Inspection methods are as follows: 1. start operation of the tractor, adjust the "speed potentiometer I" to 20HZ speed operation. 2. "speed potentiometer II", twist a circle, start local operation. 3. alternately block and release the infrared hole with your fingers, at which point the speed should change back and forth at 20HZ-23HZ. The green light flashes alternately. 4., open the whole track, fingers cover the infrared hole, frequency conversion should jump from 20HZ to 23HZ, continue to accelerate up. When you leave the infrared hole, the speed should be subtracted from the actual value 3HZ, then continue to go down to a certain point. At this point, the state jumps from yellow light to green light, and the display speed of frequency conversion should jump 3HZ from the turning point frequency. Continue to rise gradually, if act according to the above way, can confirm infrared ray no problem, should check other problems emphatically.
The seventh step: in daily production, pay attention not to let the strip block infrared stent, so as not to burn the fiber damage, check regularly for paraffin and other stolen goods blocked infrared probe, the regular cleaning of dust on the frequency converter etc..
Attached: inverter fault code Er.oL1 inverter motor overload overload Er.oLL Er.oun constant speed operation over voltage Er.ocn constant speed current infrared amplifier sensitivity adjustment settings: the switch is in the "SET" button, with white paper blocking the light, to accurately set the button "ON" button, the stability indicator (green) Flash 5 times after the jump control output indicator (red), and then take the white light transmission press "OFF" button the green light flashes 1 times, the adjustment will end the "SET" button to save "LOCK" button. Fault countermeasures: stop, restart or press the red reset button, and then problems, contact number: 13771456502
(Edit:Yang Wensen)